Overview
This article explains the scans you need to capture for a Reflected Ceiling Plan add-on. A Reflected Ceiling Plan needs your normal horizontal interior capture plus vertical interior scans for accuracy. Capturing both on the first visit gives our drafting team what it needs to draw the ceiling correctly.
In this Article
- Before You Begin
- How to Capture Scans for a Reflected Ceiling Plan
- Troubleshooting
- Frequently Asked Questions
- Related Articles
Before You Begin
- Confirm the client has ordered the iGuide Premium base package.
The Reflected Ceiling Plan add-on requires it. - Review Horizontal and Vertical Scanning Techniques for general scanning guidelines and camera positioning.
Note: You only need interior horizontal scans and interior vertical scans. Exterior scans aren’t required for this add-on.
How to Capture Scans for a Reflected Ceiling Plan
Step 1: Capture the horizontal interior scans
Capture 2 scans in each room, from roughly opposite sides, where possible. In larger rooms, add a scan about every 10 ft (3 m) in a grid pattern.
Step 2: Create a new floor for the vertical scans
Create a new floor in the project for each set of vertical scans before you start capturing them.
Step 3: Capture the vertical interior scans
Capture 1 vertical scan centered below the highest point in each room, where possible. If a room has more than one ceiling peak, capture another vertical scan below each peak.
Step 4: Hide the vertical scans before you submit
Hide or disable the vertical scans in the project before you submit it.
Note: This article covers add-on capture for regular iGuide orders. To expand your skills to commercial and architecture, engineering and construction (AEC) projects, the Advanced Capture Pro program offers training on advanced capture requirements, deliverables and workflows. Learn about the Advanced Capture Program.
Troubleshooting
Vertical scans showing in my iGuide: Hide or disable the vertical scans in the project, then resubmit.
Not sure where to place the vertical scan: Center it below the highest point of the ceiling. If the room has several peaks, capture one below each.
If the issue continues, please submit a support ticket. See iGuide Support Ticket Creation and Management.
Frequently Asked Questions
Q: Which package do I need for a Reflected Ceiling Plan?
A: iGuide Premium. The Reflected Ceiling Plan add-on requires the Premium base package.
Q: Do I need exterior scans for a Reflected Ceiling Plan?
A: No. Your normal interior capture plus interior vertical scans is enough.
Q: Are vertical scans required?
A: Yes. You need vertical interior scans along with your horizontal interior capture for an accurate Reflected Ceiling Plan.
Q: Where should the vertical scan go in a room with a vaulted or uneven ceiling?
A: Center it below the highest point. If the room has more than one peak, capture another vertical scan below each one.
Q: How many horizontal scans do I need in each room?
A: 2, from roughly opposite sides of the room. In larger rooms, add a scan about every 10 ft (3 m) in a grid pattern.
Q: What do I do with the vertical scans before I submit?
A: Hide or disable them in the project. Create a new floor for each set of vertical scans before you capture them.