Overview
This article covers physical PLANIX Pro fixes you can do in the field: seating the battery, factory resetting the system, installing a PLANIX Core or replacement Theta Z1 camera, aligning the 360° camera, and calibrating the compass.
In This Article
- Inserting the PLANIX Pro's Battery
- Factory Resetting the PLANIX Pro
- Setting Up a PLANIX Core / New Theta Z1 Camera
- Aligning the 360° Camera
- Compass Calibration
- Related Articles
Inserting the PLANIX Pro's Battery
- Press the button on the battery to confirm it has charge.
- Line the battery up with the pins, with the pull tab facing the outside of the PLANIX Pro.
- Press the battery down while gently rocking it side to side.
- Confirm the battery sits fully below the side tabs.
Factory Resetting the PLANIX Pro
- Power on the PLANIX Pro and wait until the status indicator stops blinking.
- Use a paperclip or SIM tool to hold the reset button (next to the charging port) for 3 seconds.
- Release once the status and battery indicators turn off.
Note: A factory reset clears all user settings. The Wi-Fi password resets to the camera's serial number.
Setting Up a PLANIX Core / New Theta Z1 Camera
- Remove the four M3 screws from the 360° camera mount using a #1 Phillips screwdriver.
- Attach the Theta Z1 to the mount using the provided black ¼" thumb screw.
- Connect the USB-C cable to the Theta Z1 (it only engages in one orientation).
- Attach the camera mount to the system, routing the USB cable around the plastic screw boss and between it and the adjacent flat fin.
- Reinstall the four M3 screws without overtightening. Power on the system, connect via Wi-Fi, and run lens alignment from Survey Settings (see below).
Aligning the 360° Camera
- Open the Survey interface and go to Settings.
- Run the lens-to-lidar alignment procedure any time the Theta Z1 has been removed, replaced, or reinstalled.
- Check alignment in Measure Mode 1: a corner on the floor plan should line up with the same corner in the 360° image.
Note: User-supplied Z1 cameras don't have Planitar's factory lens calibration.
Compass Calibration
The PLANIX Pro calibrates through the Survey app using a guided rotation.
- Open the Survey app on the PLANIX Pro.
- Go to the Settings menu and select Calibrate Compass.
- Follow the on-screen instructions. Slowly rotate the camera around three roughly perpendicular axes for about 15 to 20 seconds.
- If the procedure times out after 60 seconds, start it again.
For more detail, see PLANIX Camera Compass Calibration.